Re: sluggish hydraulics wedico 345d
Factory new hydraulic may in some case have some small metal contaminants left from the production process, that have not been fully removed. If just a tiny-tiny item gets stuck e.g. in the pressure relief valve, one may never get a good pressure build-up. This valve is a part of the pump, and one needs a manometer hooked up when to reinstall it again, to get the correct pressure setting.
|