Old 03-12-2012, 02:30 PM
RCP57's Avatar
RCP57 RCP57 is offline
Big Dawg On The Bone
 
Join Date: Mar 2011
Location: Vancouver Island
Posts: 3,677
RCP57 is on a distinguished road
Default Direct drive pump

I picked up a short shaft Jung pump from Vanisle and I would like to do a brushless direct drive for it. I'm looking for some advice as to what size motor I would need to make this run at 30bar with 12 volts.

Thanks Reg
Reply With Quote
  #2  
Old 03-15-2012, 02:19 AM
Vanisle Vanisle is offline
Green Horn
 
Join Date: Oct 2010
Location: Vancouver Island
Posts: 156
Vanisle is on a distinguished road
Default Re: Direct drive pump

I did some testing with a 4250 size 350kv and it struggled to restart the pump above 15 bar. I have seen on some German forums reference to a 5065 size motor being used instead of a 4250 size. Here is one:

http://www.hobbyking.com/hobbyking/s...dProduct=18176

Some 4130 motors (this number is not the outside motor size and is similar in size to a 5065) would probably also work. The best option is a Torcman motor but these are very expensive and hard to get.

You could also use a 4240/4250 size with a 3:1 planetary (from a cordless drill).
Reply With Quote
  #3  
Old 03-15-2012, 05:21 PM
carp carp is offline
Green Horn
 
Join Date: Oct 2010
Location: USA
Posts: 164
carp is on a distinguished road
Default Re: Direct drive pump

there is a thread somewhere that shows a motor coupled via direct drive i will try to find it, that 5065 motor is quite a lump what sort of runtime would you get with that? im assuming that it isnt running flat out
Reply With Quote
  #4  
Old 03-16-2012, 02:37 AM
Vanisle Vanisle is offline
Green Horn
 
Join Date: Oct 2010
Location: Vancouver Island
Posts: 156
Vanisle is on a distinguished road
Default Re: Direct drive pump

No idea about runtime with a 5065 (which is significantly larger than a 4250). I don't have one and just remember seeing someone on a German forum mention it versus a smaller motor with a 3:1 planetary. I see that RCP57 did up a driect drive (on his excavator thread) so it looks like he got it figured out.
Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 10:55 AM.


Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.