Construction Equipment If it digs, pushes, hauls dirt "off road" post it here. |
![]() |
|
Thread Tools | Display Modes |
|
#1
|
||||
|
||||
![]()
Interesting?!?! Have you confirmed the volume of oil being supplied by the pump? Disconnect the return line at the tank and put a container that is calibrated or that you can measure the actual quantity easily. Depending on how large your reservoir is, run the pump without actuating any circuits and measure the amount returned. May have to run for only 15 or 30 seconds, but confirm pump delivery. What pressure is being displayed during this test? Confirm system maximum pressure will make 275 PSI. Bottom a cylinder (either direction) by fully stroking control valve and see if relief valve actually is 275 PSI. Also, at this condition, return oil volume should match max output of pump. (You may see a slight decrease if the motor reduces RPM while under relief pressure, plus no pump is 100% efficient. Most big gear pumps can be up to 98% efficient when new. I'm guessing yours should be near that.) When you saw the system operate at 210 PSI, was that while cylinders were actually moving? Should go to 275 PSI when cylinder hits end of stroke. If there is a question about individual circuit flow, disconnect a cylinder line and put it into a container for measuring. Stroke valve fully and measure volume delivered to circuit. At same time, see if any oil is being returned via the valve return to tank. Should be practically nothing. If is significant amount, the valve may have something going goofy. Also, observe system pressure at this condition.
Ken
__________________
Big iron is awesome! |
#2
|
||||
|
||||
![]()
The best thing for me to do is share the results of all the different tests so you all know what is happening.....
The pump "should" be moving 3000cc/min or 50cc/sec. The total combined volume of the two boom cylinders is 241cc, so at 50cc/ sec it should take 4.82 seconds to fully extend both cylinders. Keep in mind this does not account for any slip in the pump and would be with no load or restrictions. 20lbs was used for the load in all the tests First test 1/4" ID suction line tank to pump, the blue1/4" OD tubing from pump to valve body, the ID of the tubing is .180", the same 1/4" OD tubing was used on the return from pump to tank. PRV set at about 275 psi on a 0-600 psi gauge. System pressure with no load and the controls in neutral was about 60 psi. It took 7.5 seconds to fully extend both cylinders and pressure was about 220 psi.....funny not what I was hoping for...lol Second test Changed the suction from the tank to pump up to 3/8" ID and changed the return line from valve to tank up to 3/8" ID as well. Pressure in the neutral position was now zero, and operating pressure dropped to about 200 psi. The time to extend the cylinders increased to just over 9 seconds. So I was getting some restriction in the return using the smaller tubing...interesting. Third test Increased the feed line from the pump to valve body to 3/8" ID tubing....no changes Forth test Check the flow rate of the 5/32" OD tubing (.106" ID)....removed the 3/8" return line and installed one 5/32" OD tubing. With the controls in neutral I turned the pump on for 30 seconds (220psi) and got almost 1500cc which is 3000cc/min, again not what I was hoping for...lol....really thought the small tubing was restricting the flow to the cylinders but that is not what is happening. Test 5 Increased pump speed 600 rpm to 2000....again very little change....scratching a hole in my head with this one...lol Last test Dropped the pump RPM back down to 1400, increased suction to 1/2" ID used the same 3/8" line pump to valve but reinstalled the blue 1/4" OD tubing on the return....the result where nearly the same as the first test. Which makes me think that some of the flow in this open center valve is still bypassing the spools even with them fully open to the cylinders. The pump is supplying the proper amount of flow but if all of that flow isn't getting to the cylinders where is it going?? (and no there isn't a leak some where...lol) |
#3
|
||||
|
||||
![]()
Oops....need to correct something in my last post.....in the first test....it should read return from valve to tank, not "return from pump to tank"
|
#4
|
||||
|
||||
![]()
I noticed in a couple pictures the suction from tank to pump you had to use a reducer. The larger the suction line the better otherwise the pump is trying to suck through a straw and will drastically effect output.
One other thing that quickly comes to mind is the prv you are using. It is the original valve relief? What is the maximum working pressure of the valve? The reason I ask is, if you have a circuit that uses a 5,000. Psi relief but you install an attachment like a clam or grapple which only needs let's say 2,200 psi, you can't just turn the 5,000 psi relief way down to the lower pressure. It must be replaced with a lower value relief. Long story short, maybe the relief is rated too high and working at 275 psi is causing it to not work properly. |
#5
|
||||
|
||||
![]()
Been pondering this... I was looking at Test #4 and you said it was delivering 3000 cc/min at 220 PSI, in neutral. I don't understand that with the valve in neutral the system is loaded so much. I'd expect a much lower back pressure (maybe 10-30 PSI) - appears there is a restriction going back to tank that is too high. Do you have a filter in the return line? If so, have you tried removing it for testing? Vented tank? Could vent be restricted? Did you get a schematic of the valve? Might look at it to see if anything unusual or unexpected in the guts of it.
Ken
__________________
Big iron is awesome! |
#6
|
||||
|
||||
![]() Quote:
|
#7
|
||||
|
||||
![]()
I'm sure many of you are getting tired of reading about the 1:1 hydraulics I'm trying to use in this build, but now that I started down this road it needs to continue until I can get it to work properly or this whole idea will be a complete waste of time and money. So if this ideas tanks, at least the rest of you will know to avoid making the same mistake and just go buy the proper system for this type of application. (That would just be to easy....lol)
Did one last test to see what might be happening to the "mysterious vanishing flow".....turns out Ken and Mario called it !!! (Ken mention this right from the start) The full scale PRV on this valve body does not like to work very well at low pressure, and I know why it appeared to be working at the beginning.....the original small return line was restricting the flow which created the illusion of proper function....lol....long story. [IMG] ![]() This time I blocked off one port on one spool valve, connected both feed lines from the other port to the ball valve and directed all the flow into the second clear container, ran the pump....and all the flow was going through the return line back to the main black container, which is normal. Next opened the control valve attached to the ball valve, when fully open all the flow was going to the second clear container and there was no flow in the return line going to the main tank (black container), which is good, no problem with the spools. While doing this I slowly closed the ball valve....and finally got the answer to the problem...there was flow in the main return line at about 200-220 psi, should not have seen any flow until the PRV setting of 275 psi was reached. In the tests before this one the only time I would see the pressure hit the 275 psi was when the cylinders would reach the end of their travel, only then would pressure spike to 275 and then drop to about 200-220...lol...the problem was right in front of me all the time, but dumb dumb just didn't catch on...yikes.. ![]() |