Quote:
Originally Posted by Lil Giants View Post
The Premacon valves are the Meinhardt design made in steel by? ...is it Jung? Why the need to have them made in steel is beyond me.

All of Fumotec's valves come from Meinhardt.
Joe I ordered valves from Premacon and they are the exact same as fumotec supply but made of steel. My reasoning was to add a little extra weight to the machine

Calum
Reply With Quote
  #2  
Old 03-23-2016, 07:20 PM
Markus K. Markus K. is offline
Newbie
 
Join Date: Feb 2014
Posts: 61
Markus K. is on a distinguished road
Default Re: 1/10 Liebherr Excavator R 984 Litronic

Hi folks,

yes, I´m using Meinhardt Valves (the big Mega Blocks - i´ve to handle about 2 liters per minute). He don´t support an online shop and he makes not as many as he could sell. Because he don´t need to, it´s not his business, it´s his hobby.
Premacon Valves are fabricated by Jung Fluid. But I can´t tell wether those are open or closed center. I simply would ask premacon via mail.
Reply With Quote
  #3  
Old 03-24-2016, 08:16 AM
filippog filippog is offline
Newbie
 
Join Date: Sep 2014
Posts: 5
filippog is on a distinguished road
Default Re: 1/10 Liebherr Excavator R 984 Litronic

Hi everybody,

Premacon valves are closed center, i have just received info from them.
Reply With Quote
  #4  
Old 03-24-2016, 01:53 PM
sinkMe sinkMe is offline
Newbie
 
Join Date: Dec 2013
Location: Norway
Posts: 10
sinkMe is on a distinguished road
Default Re: 1/10 Liebherr Excavator R 984 Litronic

Quote:
Originally Posted by filippog View Post
Hi everybody,

Premacon valves are closed center, i have just received info from them.
.. as I mention in the post above
__________________
omuller, Norway
Reply With Quote
  #5  
Old 03-24-2016, 01:59 PM
Markus K. Markus K. is offline
Newbie
 
Join Date: Feb 2014
Posts: 61
Markus K. is on a distinguished road
Default Re: 1/10 Liebherr Excavator R 984 Litronic

by the way, why do you need open center valves? You might run into problems, when using two different motions at once.
And you simply can "simulate" an open center valve by using an additional closed center. You just have to mix it to your working valves in that way, that it opens just in the moment when you don´t use the hydraulic.
Reply With Quote
  #6  
Old 03-24-2016, 03:35 PM
sinkMe sinkMe is offline
Newbie
 
Join Date: Dec 2013
Location: Norway
Posts: 10
sinkMe is on a distinguished road
Default Re: 1/10 Liebherr Excavator R 984 Litronic

Quote:
Originally Posted by Markus K. View Post
by the way, why do you need open center valves? You might run into problems, when using two different motions at once.
And you simply can "simulate" an open center valve by using an additional closed center. You just have to mix it to your working valves in that way, that it opens just in the moment when you don´t use the hydraulic.
Like loadsensing

http://www.fumotec.de/englisch/detai...sing/index.php
__________________
omuller, Norway
Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 04:11 PM.


Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.