Construction Equipment Tech Hydraulics, Electronics, General Engineering, ect in constr equip |
![]() |
|
Thread Tools | Display Modes |
|
#1
|
||||
|
||||
![]()
I went to check the bits of hose I left over from the 850 build.
Inlet to the pump = 6mm ID Outlet from pump to valve = 4mm ID Valve to Y = 4mm ID Twin returns from valve to tank = 4mmID Everything else, including from valve to relief valve = 2.5mm ID (4mm OD) The max press I run @ is 24-26bar. No leaks, no blown hoses, no blown soldered joints (so far) and I've been working the shyt out of it in this moist clay (as seen in my vids). I don't recall measuring the dia of the cyl pistons, but I would guesstimate (again) about 20mm.
__________________
Sharing knowledge is one thing that defies basic arithmetic logic --- the more you share, the more you get! Joe |
#2
|
||||
|
||||
![]()
Thanks again for the info! I didn't know the plumming was that large. My cylinders should be done soon but we are just winging it so I don't know for sure if they will work correctly on the first go. At any rate I am a long way from trying this thing anyway!
Thanks Reg |
![]() |